Power Assure CTO Recommends 10 Tips for Improving Data Center Energy Efficiency

SANTA CLARA, CA--(Marketwire - Sep 13, 2012) - Data centers are designed for reliability, usually at the expense of efficiency. Such waste increases capital and operational expenditures, and can result in finite resources being exhausted, thereby creating a situation where relentless growth threatens to outgrow the data center. 

Tweet this: @PowerAssure CTO recommends tips for improving data center energy efficiency #DCIM http://tinyurl.com/d7v3h99

Clemens Pfeiffer, CTO of Power Assure, Inc., a data center infrastructure and energy management solutions provider, outlines 10 steps IT and facility managers can take to improve efficiency without compromising reliability. These include:

  1. Reduce Cooling Power Consumption
    In a typical data center only about half of the power available is actually used by the IT equipment, with the rest going mostly to cooling. Much of that power can be reclaimed by eliminating cooling inefficiencies, upgrading the cooling system to allow for variable cooling and/or making greater use of outside air. Additional efficiency can be achieved by right-sizing the UPS and power distribution equipment. 
  2. Consolidate and Virtualize
    Poor server utilization is one of the biggest sources of waste in most data centers. Virtualizing the servers can increase overall utilization from around 10% (typical of dedicated servers) to between 20% and 30% and over 50% with more dynamic management systems. Successful consolidation and virtualization initiatives can also reclaim a considerable amount of rack space and stranded power. 
  3. Calibrate and Monitor Cold Aisle Temperatures
    A best practice today is to adopt a hot/cold aisle configuration and increase the cold aisle inlet temperatures to 80.6°F (27°C) as recommended by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). But hot/cold aisle configurations can create hot spots that waste power and cause outages. Balancing the equipment, and then calibrating and continuously monitoring the cold aisle temperature maximizes cooling efficiency and minimizes problems. 
  4. Match Server Capacity to Load in Real-Time
    Even the best virtualized and recently refreshed server configurations waste power during periods of low application demand. Total server power consumption can be reduced by up to 50% by matching online capacity to actual load in real-time. Runbooks can be used to automate the steps involved in power-capping and/or de-/re-activating servers, whether on a predetermined schedule or in response to unanticipated events. 
  5. Correlate IT/Facility Emergency Procedures
    The lack of complete correlation between facility and IT emergency procedures can unnecessarily cause and/or extend application outages. Fully correlating and automating these procedures minimizes the impact outages have, and also reduces the UPS/generator load during an outage, thereby extending the availability of power. 
  6. Determine Actual Power Consumption
    Older equipment often uses power inefficiently, and newer servers with a high idle/peak swing (above 50%) can overload circuits more frequently when incorrectly allocated and aggregated. Using the PAR4 methodology specified in the Underwriters Laboratories UL2640 standard to determine actual power consumption makes it possible to maximize server capacity while eliminating the risk of overloading circuits under peak utilization. 
  7. Eliminate the Transfer Switch
    While the use of an automatic transfer switch between the grid and the generator is a common configuration, an AC (Alternate Current) or DC (Direct Current) distribution bus is far more efficient and just as effective during a power outage. The bus configuration seamlessly integrates all sources of power, including any on-site fuel cells and solar/wind energy, and enables generator maintenance cycles to be put to good use. 
  8. Load-Balance by Following the Moon
    Many organizations operate redundant data centers to satisfy business continuity needs, but very few take full advantage of this powerful configuration. Having multiple, strategically-located data centers enables loads to be shifted to where power is currently the most stable and the least expensive. Because power is invariably most abundant and least expensive at night, such a "follow the moon" strategy can result in considerable savings. 
  9. Foster IT/Facility Management Consistency
    Maximizing data center efficiency (which also helps minimize capital and operational expenditures) will require an unprecedented level of cooperation between IT and facility managers. At a minimum, all aspects of monitoring and managing the data center infrastructure should become both consistent and pervasive across the IT and facilities organizations. Achieving the best results requires a holistic view of power consumption, environmental conditions and resource utilization together with utility grid and weather conditions. Such transparency can help delay new data center construction and expensive equipment purchases and should be on the must have list for every CFO.
  10. "Monetize" the Data Center
    Electricity is expensive, and data centers will continue to consume an ever-increasing amount of it. The AC or DC distribution bus configuration (see Tip #7) better prepares the organization to reap financial rewards by participating in the Smart Grid's ancillary energy markets and demand response events, or through distributed generation via net metering with a microgrid powered by sources of renewable energy. 

"Data centers waste a substantial amount of energy because they are deployed and configured for peak capacity, performance and reliability, usually at the expense of efficiency," said Pfeiffer. "Such waste unnecessarily increases capital and operational expenditures, and can result in finite resources (particularly power and space) being exhausted, thereby creating a situation where the organization might outgrow its data center. But there are steps IT managers can take, however, to improve overall data center efficiency, sometimes dramatically, without adversely impacting on capacity, performance or reliability."

About Power Assure (www.powerassure.com)
Power Assure is a leading developer of Data Center Infrastructure and Energy Management software for large enterprises, government agencies, and managed service providers. Power Assure's solutions provide visibility, intelligence, analytics and automation to help CIOs, IT directors, and facilities managers optimize capacity, service levels, and power consumption within and across data centers. Headquartered in Santa Clara, CA, the company is privately held with funding from ABB Technology Ventures, Dominion Energy Technologies, Draper Fisher Jurvetson, Good Energies, Point Judith Capital, as well as a grant from the Department of Energy. Power Assure partners include ABB, Cisco, Dell, IBM, In-Q-Tel, Raritan, UL and VMware.